Chapter 6 Operating Instructions
ICR890 High-end CCD Camera System
80 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011325/0000/2006-10-24
Operation
6.2.4 Default setting for the SOPAS-ET Configuration Software
6.3 First startup
The ICR890 System is optimized to the reading conditions on site via the SOPAS-ET
Configuration Software. Starting point for this is the factory default setting which can be
adjusted to optimize the system. The SOPAS-ET Configuration Software is used to create an
application-specific parameter set which can be loaded into the system and saved/archived
as a project file (spr file with configuration data) on the PC.
Note The ICR890 System does not provide a reading result in configuration mode.
Parameter Value
User interface language
English
1)
Units of length Metric
User group (operating level) Machine operator
Download parameter for changes Immediate, temporary (RAM of the ICR890
System)
Upload parameter after online switching Automatic
Window layout 3 (project tree, help, work area)
Serial communication COM 1: 9,600 Bd/19,200 Bd, 8 data bits, 1 stop
bit, no parity
1) the software has to be restarted after changes
Tab. 6-1: Default setting for the SOPAS-ET Configuration Software (excerpt)
Abb. 6-1: Configuration with SOPAS-ET
Opened project file
with current
parameter set
PC with Configuration
Software SOPAS-ET
Saved project file (*.spr)
with archived parameter
set
System ICR890
Parameter set in the
main memory of the system
Permanently saved
parameter set
Factory default setting of
the system
EEPROM
ROM
RAM
RAM
Database
(hard drive)