Chapter 3 Operating Instructions
ICR890 High-end CCD Camera System
28 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011325/0000/2006-10-24
Product description
3.2.3 Electrical installation requirements
Power supply (via MSC800): 100 to 264 V AC/50 to 60 Hz
Reading pulse sensor (start/stop), e.g. photoelectric reflex switch (included in delivery):
For detecting an object with external reading pulse
Additional appropriate reading pulse sensor (stop), e.g. photoelectric reflex switch: For
detecting the end of pulse with extended external reading pulse
Preconfigured MLG Light Grid(included in delivery): when reading from above to detect
the object distance
VMS4xx/5xx Volume Measurement System: when reading from the side or for multi-
side reading to detect the object distance
Suitable incremental encoder, e.g. no. 2039455 (resolution 10 mm (394 mil)/pulse) or
no. 2039457 (resolution 0.2 mm (7.9 mil)/pulse) when using the VMS4xx/5xx.
Device is included in delivery depending on the system configuration
Host processor with RS 232, RS 422/485 data interface or Ethernet: For further
processing of the reading data via MSC800 also PROFIBUS-DP
Suitable visualization PC or PLC: To display the system status
Connection cables: See Chapter 5.3.4 Assembled cables (overview), page 63
3.2.4 Operation requirements
PC in the following version:
Minimum Pentium III, 500 MHz, 128 MB RAM, CD drive, RS 232 serial data interface
or Ethernet interface card, mouse (recommended) and colour monitor
(recommended resolution 1,024 x 768 pixels)
Operating system Windows 98
TM
, Windows NT4.0
TM
, Windows ME
TM
, Windows
2000
TM
or Windows XP
TM
Free storage space on the hard drive: Approx. 100 MB for the SOPAS-ET
Configuration Software (V. 2.08) with help files and approx. 70 MB for “Acrobat
Reader“
Connection cables see Chapter 5.3.4 Assembled cables (overview), page 63
PC HTML browser, e.g. Internet Explorer
TM
: For online help system to the SOPAS-ET
Configuration Software
Special PC for client display of the processed camera image information in real time
equipped with the following:
Two 1 GBit Ethernet “IntelPro/1000 network card“ interface cards with 8254x
(x = 0, 1, 2, 4, 5, 6, 7) chip set
GigE vision standard licence for real time image data transfer
Vista de pagina 27