Chapter 5 Operating Instructions
ICR890 High-end CCD Camera System
62 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011325/0000/2006-10-24
Electrical installation
5.3.3 Electrical connections of the MSC800 (overview)
Please refer to the MSC800 Operating Instructions (no. 8011540) for connections of the
MSC800-0000 logic controller.
The following interfaces are realized via the MSC800-0000 connections:
-
Abb. 5-5: MSC800-0000 logic controller: Position of the electrical connections
Connection Design
Number of
poles Function
PROFIBUS D-Sub 9, socket Main data interface
USB 2 USB 4 Auxiliary data interface
ETHERNET 3 RJ-45 8, socket Auxiliary data interface
ETHERNET 2 RJ-45 8, socket Auxiliary data interface
USB 1 USB 4 Auxiliary data interface
ETHERNET 1 RJ-45 8, plug Main data interface
AUX 2 Block 14, terminals
Auxiliary data interface
(RS 232, RS 422/485)
AUX 1 D-Sub 9, plug
Auxiliary data interface
(RS 232, RS 422/485)
OUT Block 14, terminals Digital switching outputs (system status)
IN Block 12, terminals Digital switching inputs
TRIGGER Block 12, terminals Digital switching inputs (reading pulse)
INC Block 12, terminals Digital incremental encoder inputs
HOST (1/2) Block 14, terminals Main data interface (RS 232, RS 422/485)
CAN 2 Block 12, terminals Input/Output CAN-SENSOR network 2
CAN 1 Block 12, terminals Input/Output CAN-SENSOR network 1
POWER Block 8, terminals Power supply input 24 V DC
Tab. 5-9: MSC800-0000 logic controller: Function of the electrical connections (overview)