Chapter 3 Operating Instructions
ICR890 High-end CCD Camera System
42 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011325/0000/2006-10-24
Product description
3.5.2 LEDs of the ICD890 Camera
There are five LEDs for the electrical connections of the ICD890 Camera. These LEDs
display the operating status, the status of the reading result, the illumination switch status,
necessary maintenance or service tasks and data transfer to the serial main data interface.
The LEDs indicate the following:
Fig. 3-14: LEDs at the ICD890 Camera
LED Colour Indication
DEVICE READY green
Lights up after switching on and a successful self-test
Lights up permanently during reading operation
Goes off when the configuration mode changes
RESULT green
Lights up during reading operation after a successful reading (default setting: Good Read, 100 ms)
IllUMINATION green
Lights up during reading operation if the ICI890 Illumination of the camera is switched on (depends
on the reading pulse)
SERVICE red Flashes if system maintenance is required
Lights up permanently if the system requires servicing
DATA yellow
Flashes during reading operation if data is being transferred between the ICR890 System and the
main data interface at the host
Tab. 3-5: LED indications