
Operating Instructions Chapter 3
ICR890
Product description
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 37
3.4.8 Code configuration
The ICR890 System can decode the following code types:
1-D codes (bar codes)
• Codabar
• Code 39
• UPC/EAN family
• 2/5 Interleaved
• Code 93
• Code 128 family
2-D codes
• Data Matrix EEC200
• PDF417 (in preparation)
The code types for 1-D and 2-D codes can be selected using the SOPAS-ET Configuration
Software:
P
ROJECT TREE, ICR890, PARAMETER, 1D CODE CONFIG., register tab SYMBOLOGIES
PROJECT TREE, ICR890, PARAMETER, 2D CODE CONFIG., register tab SYMBOLOGIES
The selected code types can be configured individually. The SOPAS-ET Configuration
Software has individual register tabs for each type.
3.4.9 Data processing
Start/Stop operation
There is only one object in the reading area during start/stop operation, i. e. all the read
codes should be unambiguously assigned to the object. The start and stop of the reading
process control two reading pulse sensors at the beginning and at the end of the reading
area as standard (Fig. 3-12, page 38). The distance between each sensor is determined by
the size of the reading area. The reading process can be alternatively controlled with
command strings via the data interface. The output of the reading results is carried out
either at the end of the reading pulse (the rear edge of the object has left the end of the
reading area) or during the reading pulse if certain parameterizable conditions have been
fulfilled.
Comentarios a estos manuales