Operating Instructions Chapter 3
ICR890
Product description
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 27
3.2.2 Installation requirements
• Typical space requirements above the highest object (for reading from above):
application-specific
• Unobstructed view of the objects for the ICR890 System
• Stable installation frames with sufficient load capacity and measurements suited to the
ICR890 System (see Chapter 9.5 System dimensional drawing ICR890, page 108)
• Four 180° brackets for the ICR890 System and the deflection mirror (included in
delivery)
• Shock absorbent and vibration free attachment
Note An installation frame made of 80 mm (3.15 in) item aluminium profiles can be used for
simple system installation (Fig. 3-4). The 180° brackets are aligned to these profiles.
Requirement Value Comment
Max. reading
distance
3,000 mm (118.2 in) from reading window (Fig. 3-3, page 26)
Shortest
permissible
distance to the
object
1,400 mm (55.2 in)
Aperture angle
25
°
Work area up to 2,400 mm (94.6 in)
Max. track width 1,000 mm (39.4 in) also see reading area diagram in Fig. 9-1,
page 106
Achievable ICD890
Camera resolution
depends on the distance to the object and on the
conveyor speed (see Chapter 3.4.12 Data
interfaces, page 39)
Max. conveyor
speed
4.8 m/s (945 ft/min) with pixel size 0.25 mm (9.8 mil)
Tab. 3-3: General system requirements (standard device)
Fig. 3-4: Example of simple system installation on the installation frame