Operating Instructions Chapter 3
ICR890
Product description
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 27
3.2.2 Installation requirements
Typical space requirements above the highest object (for reading from above):
application-specific
Unobstructed view of the objects for the ICR890 System
Stable installation frames with sufficient load capacity and measurements suited to the
ICR890 System (see Chapter 9.5 System dimensional drawing ICR890, page 108)
Four 180° brackets for the ICR890 System and the deflection mirror (included in
delivery)
Shock absorbent and vibration free attachment
Note An installation frame made of 80 mm (3.15 in) item aluminium profiles can be used for
simple system installation (Fig. 3-4). The 180° brackets are aligned to these profiles.
Requirement Value Comment
Max. reading
distance
3,000 mm (118.2 in) from reading window (Fig. 3-3, page 26)
Shortest
permissible
distance to the
object
1,400 mm (55.2 in)
Aperture angle
25
°
Work area up to 2,400 mm (94.6 in)
Max. track width 1,000 mm (39.4 in) also see reading area diagram in Fig. 9-1,
page 106
Achievable ICD890
Camera resolution
depends on the distance to the object and on the
conveyor speed (see Chapter 3.4.12 Data
interfaces, page 39)
Max. conveyor
speed
4.8 m/s (945 ft/min) with pixel size 0.25 mm (9.8 mil)
Tab. 3-3: General system requirements (standard device)
Fig. 3-4: Example of simple system installation on the installation frame