Operating Instructions Chapter 5
ICR890
Electrical installation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 57
Note Please refer to the MSC800 Operating Instructions (no. 8011540) for connection to the
MSC800.
No.
MSC800
connection
Function Connection to ... Cable to be used
1 Power supply
input terminals
Power supply of the MSC800 Mains voltage 100 to 264 V AC/50 to 60 Hz Cable provided by the
client
2 TRIGGER Reading pulse trigger signals External reading pulse sensor Included in delivery
3 HOST or
AUX
Detection of object height MLG Light Grid (RS 485) Included in delivery
4 INC Increment signals Incremental encoder
(resolution 0.2 mm (7.9 mil)/incr.)
Included in delivery
5 HOST or
ETHERNET or
PROFIBUS
Data output of the reading
result at the ICR890 System
Host processor (RS 232, RS 422/485 or
Ethernet)
Cable provided by the
client
6 OUT (1/2) Indication of system status PLC (optional) Cable provided by the
client
7 AUX or
USB or
ETHERNET
Configuration/Diagnosis Standard PC, temporarily Cable provided by the
client
Tab. 5-3: ICR890 System (stand-alone device) with MSC800: Overview of the MSC800 connections which have to be established
Vista de pagina 56