Operating Instructions Chapter 4
ICR890
Installation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 49
4.3 Installing and adjusting the device
The position of the components on the installation frame is specified project specifically in
a dimensional sheet (Fig. 4-1, page 46). The specifications have to be adhered to as far as
possible during installation, since the values influence the configuration of the system to
some extent.
Note A final (fine) adjustment of the components can only occur during startup (see Chapter 6.3,
page 80). Prerequisite for this is the complete electrical installation of the system (Chapter
5, page 53).
In order to facilitate component alignment, the deflection mirror and the unit consisting of
the illumination and the camera are attached to the installation frame via 180° brackets.
After loosening the clamping screws, the angle of the brackets can be adjusted from 0° to
180° as required. To achieve this, the clamping screws can be screwed into the various
threaded holes.
Abb. 4-6: Position of the components
Distance of the illumination and the
camera to the deflection mirror
Reference point
Reading location
15°
ICI890 Illumination
with ICD890
Camera
Deflection mirror
Direction of transport
Distance of the deflection mirror to the reference point
Abb. 4-7: 180° bracket for the deflection mirror and the illumination
Clamping screws
Bore holes for
fastening screws
Grooves for
guide pins
Bolts with slot nuts
for attachment to the
installation frame
Pivotal point