Chapter 6 Operating Instructions
CLV490 Bar Code Scanner
6-16 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Operation
Event-controlled focus position switchover (alternative)
Event-controlled focus position switchover can be used if the autofocus function does not
provide the expected accuracy for the application. Event-controlled focus position
switchover is required in the following cases, for example:
Conveyed material with a black surface (e.g. vehicle tires)
The laser light emitted by the CLV490 is absorbed by the surface of the material, which
means that the distance measurement may no longer be sufficiently accurate.
Conveyed material with highly reflective surfaces (e.g. anti-static bags)
Conveyed material with bar codes on the front edge in the conveying direction. At high
conveyor speeds, the CLV490 can no longer adjust the focus in time.
Scanning frequency Ö R
EADING CONFIGURATION tab Ö READING PARAMETERS section
Blank zone Ö R
EADING CONFIGURATION tab Ö READING PARAMETERS/START/STOP RATIO section
Poor quality bar code print (e.g. small contrast or scattered print) Ö R
EADING
CONFIGURATION tab Ö CODE LABEL/BACKGROUND CHARACTERISTCS section
If reading bar codes with small height (bar lenght) using the SMART decoder Ö
C
ODE CONFIGURATION tab Ö DECODER section/SMART PARAMETERS button
Action Settings in CLV-Setup
1. Set up distance
configurations
Ö READING CONFIGURATION tab
Ö READING AREA section
Ö DISTANCE CONFIGURATION button
Ö DISTANCE CONFIGURATION tab
Focus position
Oscillating mirror:
additionally: Oscillating mirror amplitude CW
Ö ASSIGNEMENT TABLE tab
Index
Valid configurations
To restrict the reading area for all valid distance configurations
proceed as described in Table 6-4, Page 6-11, reading angle
limits
2. Select focus position
switchover (refered to the
start of the reading interval)
Ö READING CONFIGURATION tab
Ö FOCUS CONTROL sections
Ö INPUTS/SERIAL/AUTOFOCUS
immediate or synchronous (default setting) or
latched (special application)
3. I
NPUTS/SERIAL trigger source:
select function for "IN 3"
and "IN 4" switching inputs
Ö DEVICE CONFIGURATION tab
Ö ASSIGNMENT OF INPUTS section
Ö IN 3
–Focus control
Ö IN 4
–Focus control
Table 6-8: Guide: Configuring focus position switchover
d) Parameterizing optical reading characteristics