Chapter 6 Operating Instructions
CLV490 Bar Code Scanner
6-34 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Operation
Parameterizing reading trigger in the CLV490:
Parameterizing tracking in the CLV490:
Explanation Object tracking takes place in every CLV490 in the system. For this purpose, each CLV490
continuously compiles an internal object list. When in slave mode, the CLV490 receives the
required tracking information for the objects in the reading field from the OTC400 via the
CAN bus.
As soon as a successful reading has been made, the CLV490 sends the reading result to
the OTC400 via the CAN bus. The OTC400 then compiles the results with the same name
Select fixed focus and
parameterize one distance
configuration
see Table 6-8, Page 6-16
Forwarding distance
informations (optional)
Ö READING CONFIGURATION tab
Ö FOCUS CONTROL section
Ö AUTOFOCUS PARAMETERS button
–A
UTOFOCUS OPTIMIZATION PARAMETERS button
–O
BJECT HEIGHT PASSING IN OTS MODE section
–Active
Action Settings in CLV-Setup
Parameterize reading trigger
Ö DEVICE CONFIGURATION tab
Ö READING TRIGGER SOURCE section
OTS trigger
Table 6-19: Guide: Parameterizing reading trigger in the CLV490 for object tracking mode with
OTC400
Action Settings in CLV-Setup
1. Define scanner position
referred to conveyor belt
Ö DEVICE CONFIGURATION tab
Ö SCANNER POSITIONS PARAMETERS button
Ö ANGLES section
Angles: alpha, beta and gamma
Ö COORDINATES section
x-, y- and z-coordinates
2. Parameterize scale factor for
incremental pulse
Ö DEVICE CONFIGURATION tab
Ö DISTANCE PER ENCODER PULSE Section
Value
(in agreement with incremental encoder and OTC400)
3. Define release points
Ö DEVICE CONFIGURATION tab
Ö TRACKING PARAMETERS button
Ö RELEASE POINTS section
Focus release point: value
Object release point/End of reading field/Output data: value
4. Define label assignment
tolerance for object gaps
Ö DEVICE CONFIGURATION tab
Ö TRACKING PARAMETERS button
Ö LABEL ASSIGNMENT TOLERANCE section
Automatic or
Fixed Tolerance: value
Table 6-20: Guide: Parameterizing tracking in the CLV490 for object tracking mode with OTC400
Action Settings in CLV-Setup
Table 6-18: Guide: Parameterizing focus control in CLV490 for object tracking mode with OTC400