SICK CLV490 Instrucciones de operaciones Pagina 101

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 270
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 100
Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-23
Operation
Parameterize reading trigger:
two external sensors
or
Ö DEVICE CONFIGURATION tab
Start (sensor 1):
Ö READING TRIGGER SOURCE section
Sensor Input (Active High) or
Sensor Input (Active Low)
Ö READING TRIGGER PARAMETERS button
Ö DEBOUNCING SENSOR section (also for sensor 2 on IN 4)
Standard or
–Fast or
Time controlled: value
Ö FIRST TRIGGER SENSOR section
Edge or
Level
Stop (sensor 2):
Ö END OF READING INTERVAL section
generated by IN 4
Ö DEVICE CONFIGURATION tab
Ö ASSIGNMENT OF INPUTS section
Ö IN 4
Reading Trigger Stop (Active High) or
Reading Trigger Stop (Active Low)
Output of reading result referred to beginning of reading
interval:
Ö OUTPUT ON GOOD READ section
End of reading gate or
Immediate or
–End of Label
Ö Using End of label: READING TRIGGER PARAMETERS button
Ö END OF LABEL/FREE-RUNNING section
Timeout
Note:
Connect external sensor 1 (start) to "Sensor" switching input and
sensor 2 (stop) to "IN 4" switching input!
Action Settings in CLV-Setup
Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone
configuration (contd.)
Vista de pagina 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 269 270

Comentarios a estos manuales

Sin comentarios