8.5.5 Malfunctions in Reading mode: oscillating mirror errors
¾ Check whether the "Device Ready" LED lights up.
If the LED does not light, see Table 8-5, Page 8-9.
Malfunction Possible cause Remedy
1. The oscillating mirror does not move. Incorrect operating mode set in the
CLV490.
In the "CLV-Setup" program:
choose the OSCILLATING MIRROR tab, OSCILLA-
TING MIRROR section.
Is OSCILLATING WITH FIX AMPLITUDE or OSCILLA-
TING WITH VARIABLE AMPLITUDE selected?
2. The oscillating mirror oscillates with
maximum deflection (40 CW), even
though a variable amplitude, e. g. 10 CW,
is set in the distance configuration 1.
• O
SCILLATING WITH FIX AMPLITUDE set in the
CLV490 by mistake.
• The oscillating amplitude is paramterized
in the wrong distance configuration
(here: no. 2).
• The distance configuration (focus
position) was not changed.
• From the OSCILLATING MIRROR tab, choose
OSCILLATING WITH VARIABLE AMPLITUDE.
Download to the CLV490!
• In the "CLV-Setup" program: choose the
READING CONFIGURATION tab, click the
DISTANCE CONFIGURATION button. Is the
amplitude value set in the correct di-
stance configuration (here: no. 1)?
• In the "CLV-Setup" program: choose the
DEVICE CONFIGURATION tab. Assignment of
Inputs for "IN 3" and "IN 4": is focus
control selected?
Connect sensors to the switching inputs.
Check sensor wiring (see Fig. 5-6,
Page 5-23).
Measure output signal at sensor
3. One-Shot: The One-Shot function cannot
be triggered (sensor correctly connected
to the "IN 3" or "IN 4" switching input).
• Trigger source incorrectly parameterized
• "IN 3" or "IN 4" switching input has not
been assigned this function.
• In the "CLV-Setup" program:
choose the O
SCILLATING MIRROR tab. Is
"one-shot" selected?
• Choose D
EVICE CONFIGURATION tab.
A
SSIGNMENT FOR INPUTS section: "IN 3" or
"IN 4": is trigger "One-Shot" selected?
Table 8-11: Troubleshooting: oscillating mirror errors in Reading mode