Chapter 10 Operating Instructions
CLV490 Bar Code Scanner
10-54 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Appendix
ding trigger in coded form in output window 2.
4. To return to Reading mode, click on the R
EADING MODE option field.
The "Device Ready" LED lights up.
Note The parameter values directly changed with command strings in the CLV490 are registered
and shown only after the parameter set is uploaded from the CLV490.
Outputting command strings for all the parameter settings
You can output a list of all the parameter settings configured with CLV-Setup in ASCII format.
To do so, proceed as follows:
1. In the menu bar, choose E
XPORT PARAMETERS under CLV490.
Starting from the default settings, CLV-Setup collects all the command strings required
to parameterize the default configuration and customized settings.
The S
ELECT FILE NAME FOR PARAMETER EXPORT dialog box is displayed.
2. Enter a file name and click the S
AVE button.
CLV-Setup saves the data as a text file in the directory shown.
You can open this text file using any Windows text editor.
If the commands are sent from the host/PLC to the CLV490 for configuration, note that "3
EEW" has to be sent as the last command to ensure that they are permanently transferred
to the CLV490 (EEPROM).