Chapter 5 Operating Instructions
CLV490 Bar Code Scanner
5-22 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Electrical installation
3. Switch on the PC and power supply to the SICK Connection Module.
4. Set the communication parameters (see Chapter 10.6.3 Starting CLV-Setup,
Page 10-46).
Tip
In the default configuration, the auxiliary interface outputs the reading result in reading
diagnosis mode.
You can change the operating mode to M
ONITOR HOST INTERFACE, to MONITOR HOST INTERFACE 2,
A
UXILIARY INPUT or EXTERNAL DATA STRING INPUT on the AUXILARY INTERFACE tab in the "CLV-
Setup" program.
5.5.7 Connecting the "Sensor" switching input
If a reading procedure is to be triggered on the CLV490 by an external sensor, the reading
pulse sensor must be connected to the "Sensor" switching input. This trigger type is select-
ed in the default setting of the CLV490. Fig. 5-5 shows the connections for the "Sensor"
switching input. Table 5-23 contains the characteristic data for this input.
¾ Connect the reading pulse sensor as shown in Fig. 5-5.
Tip
You can change the switching mode (polarity, debouncing, response for first pulse after
power-up) of the "S
ENSOR" switching input on the DEVICE CONFIGURATION tab in the "CLV-
Setup" program.
¾ Click the R
EADING TRIGGER PARAMETERS button.
Enter the values in the dialog box displayed.
Perform a download to the CLV490.
Fig. 5-5: Connections of the "Sensor" switching input
Sensor
IN GND
GND
GND
GND
OUT
2k6
1
3
9
5
1
3
9
5
V
S
V
S
V
S
V
S
CLV
V
S
= 18 to 30 V DC for CLV490 without heater,
24 V DC +20 % /–10 % for CLV490 with heater
Switch
PNP sensor
Switching mode Current at the input starts the reading interval on the CLV490.
(default: active high, debouncing: 20 to 30 ms (standard))
Properties – optodecoupled, non-interchangeable
– can be connected to PNP output on a sensor
Electrical values
Low: –30 V
≤ V
I
≤ +2 V High: +7 V ≤ V
I
≤ +13 V
Table 5-23: Characteristic data of the "Sensor" switching input