Chapter 6 Operating Instructions
CLV 490 Bar Code Scanner
6-10
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Operation
Parameterization autofocus function (Part 2):
•
Area parameters tab D
EVICE
C
ONFIGURATION
Edit Scanner position and Edit Tracking
Parameters (in OTS mode only)
•
Teach-in/show ambient background T
OOL
menu Device functions
Fig. 6-2
shows a 2D example of how the visible range of the CLV is adjusted using the
parameters "Limit values: scan angle limitation" and "Limit value: autofocus space".
Parameter Minimum Distance Differential background Differential background
and Tracking
Condition
1 object in reading field per
reading interval
1 object in reading field per
reading interval
No. of objects in the reading
field per reading interval:
≥
1
1. Limits:
autofocus limitation
✖❍❍
2. Limits:
Scan angle limitation
✖❍❍
3. Limits:
oscillation angle limitation
1)
✖✖✖
4. Limits:
autofocus space
–
❍❍
5. Edit scanner position
(angles):
angle alpha, beta, gamma
–
✖✖
6. Edit scanner position
(coordinates):
Coordinates x, y, z
–
✖✖
7. Edit tracking parameter:
focus release point
––
✖
8. Teach-in background –
❍❍
✖
: required
❍
: optional 1) for line scanners with oscillating mirror
Table 6-5: Guide: Parameterizing the autofocus function (Part 2)
Fig. 6-2: Narrowing the visible range using limit values
Scan angle
limitation
Autofocus space