10.10.6 Parameterize the CLV with the "CLV-Setup" program
1. Connect the PC to the CLV’s terminal interface (see
Chapter 5.5.5 Connecting the CAN
interface, Page 5-15
)
2. Start Windows and the "CLV-Setup" program on the PC.
3. Invoke the CLV 490’s default setting in the "CLV-Setup" program
(see
Chapter 6.1 Overview of steps for starting up the CLV, Page 6-1
).
4. Parameterize the CLV with the help of
Chapter 6.4.4 Guide to parameterization menu,
Page 6-8
and the tab cards by following the steps described.
5. After completing parameter value alterations, download them to the CLV!
(see
chapter Chapter 6.4.1 Configuring the CLV via the user interface of CLV-Setup,
Page 6-5
).
1. Setting up the autofocus function (Part 1): R
EADING
C
ONFIGURATION
tab
Set the following parameters:
Scanning frequency: 800 Hz
Start/stop ratio: auto
Trigger for focus position changeover: autofocus
Autofocus mode: differential background
Click on the E
DIT
AUTOFOCUS
button.
The E
DIT
AUTOFOCUS
dialog window then opens.
Set the following parameters on the A
DJUSTMENTS
tab (
Fig. 10-46, Page 10-59
):
Preference of focus distance: Fix focus position: 1200 mm
(approx. 100 mm above the packet with the smallest height)
Fig. 10-45: Parameterization example: settings on the "Reading Configuration" tab