Operating Instructions Chapter 6
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-7
Operation
Device Configuration
This tab and further dialog boxes are used to set the following:
Device number
Source of the Reading trigger mode
Laser timeout
Output time of the Reading result referred to the start of the reading interval
Scanner position parameters (the position of the CLV in the area)
Tracking parameters
Object polling parameters
Output filter of the reading result (host interface)
Physical arrangement for data output via the host interface
(stand-alone, master/slave)
Functional assignment of the IN 3 and "IN 4" switching inputs
Functional assignments of the "Result 1 ... Result 4" switching outputs
Start option for accessing the parameter set
Code position comparison
Code Configuration
This tab and further dialog boxes are used to set the following:
Type of active decoder (SMART or standard decoder)
Evaluation routines for individual code types
Number of identical reads (multiple reads)
Minimum and maximum number of bar codes to be read/output
Kind of Start/Stop recognition
Activation of the comparison of the code position for the separation of identical bar co-
des
Recommendation
To enhance the reading reliability with fast applications, only activate those code types
and code lengths that are actually relevant.
Host Interface
This tab and further dialog boxes are used to set the following:
Destination of the read result date strings (host interface or CAN interface)
Active physical interface (RS 422/485 or RS 232)
Data format and transmission rate
Data transmission protocol
Start and stop characters of the interface protocol
Data Strings
This tab and further dialog boxes are used to set the following:
Data output format of the host interface (telegram format)
Constants and reading diagnosis data in the header, separator and terminator
Arrangement of the separators in the data string
Output format for no reads and contents of the error string
Test string function
Output sequence and sort criteria for reading more than one bar code per reading pulse
Format mask and its structure