Chapter 10 Operating Instructions
CLV 490 Bar Code Scanner
10-2
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Appendix
10.2.2 Overview of diagrams
Line scanner
Line scanner with oscillating mirror
CLV-Type Resolution Scanning method Diagram Page
CLV 490-0010/-0011 Standard density Line scanner Reading field height/resolution as a function of reading distance 10-3
CLV 490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/40
°
10-4
CLV 490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/56
°
10-5
CLV 490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.50 mm/40
°
10-6
CLV 490-0010/-0011 Standard density Line scanner Min. and max. reading distance (DOF) for 0.50 mm/56
°
10-7
CLV 490-0010/-0011 Standard density Line scanner Characteristics field scanning frequency 10-8
CLV 490-2010/-2011 High density Line scanner Reading field height/resolution as a function of reading distance 10-16
CLV 490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.25 mm/40
°
10-17
CLV 490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/40
°
10-18
CLV 490-2010/-2011 High density Line scanner Min. and max. reading distance (DOF) for 0.35 mm/56
°
10-19
CLV 490-2010/-2011 High density Line scanner Characteristics field scanning frequency 10-20
CLV 490-6010/-6011 Low density Line scanner Reading field height/Tilt as a function of reading distance for
0.5 mm
10-27
CLV 490-6010/-6011 Low density Line scanner Min. and max. reading distance (DOF) for 0.5 mm/40
°
10-28
CLV 490-6010/-6011 Low density Line scanner Min. and max. reading distance (DOF) for 0.5 mm/60
°
10-29
CLV 490-6010/-6011 Low density Line scanner Characteristics field scanning frequency 10-30
Table 10-2: Overview of specification diagrams for the line scanner
CLV-Type Resolution Scanning method Diagram Page
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Reading field height/resolution as a function of reading
distance
10-9
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40
°
10-10
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50
°
10-11
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/40
°
10-12
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/50
°
10-13
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Characteristics field scanning frequency 10-14
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Deflection range 10-15
CLV 490-3010/-3011 High density L.s. with osci. mirror Reading field height/resolution as a function of reading
distance
10-21
CLV 490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.25 mm/40
°
10-22
CLV 490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40
°
10-23
CLV 490-3010/-3011 High density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50
°
10-24
CLV 490-3010/-3011 High density L.s. with osci. mirror Characteristics field scanning frequency 10-25
CLV 490-3010/-3011 High density L.s. with osci. mirror Deflection range 10-26
CLV 490-7010/-7011 Low density L.s. with osci. mirror Reading field height/Tilt as a function of reading distance for
0.5 mm
10-31
CLV 490-7010/-7011 Low density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/40
°
10-28
CLV 490-7010/-7011 Low density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/50
°
10-29
CLV 490-7010/-7011 Low density L.s. with osci. mirror Characteristics field scanning frequency 10-32
CLV 490-7010/-7011 Low density L.s. with osci. mirror Deflection range 10-33
Table 10-3: Overview of specification diagrams for the line scanner with oscillating mirror