Chapter 10 Operating Instructions
CLV 490 Bar Code Scanner
10-62
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Appendix
Confirm the dialog box with "OK".
3. Set the reading pulse source: D
EVICE
C
ONFIGURATION
tab
In the R
EADING
T
RIGGER
M
ODE
group click the option Sensor Input (Active High).
In the Output on Good read group click the option End of label.
Confirm the dialog box with "OK".
Fig. 10-51: Parameterization example: "Edit Scanner Position/Coordinates" dialog window
Fig. 10-52: Parameterization example: Settings on the "Device Configuration" tab