Operating Instructions Chapter 3
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
3-9
Product description
The meaning of the LEDs in the various operating modes/functions is shown in
Table 3-2
and
Table 3-3
.
CLV without external parameter memory
Operating mode LED Display Function
Start Device Ready
Green
Lights up after power-up if the self-test was successful
Subsequent behavior depends on selected start option
S
tart option: S
TART
WITH
EXTERNAL
P
ARAMETERS
(
DEFAULT
)
Lights up constantly (CLV has loaded internal parameter set)
Start option: S
TART
WITH
INTERNAL
P
ARAMETERS
:
Lights up constantly (CLV has loaded internal parameter set)
Start option: S
TART WITH
C
OPY
I
NTERN ->
E
XTERN
:
Blinks constantly together with the "Read Result" LED
1)
(CLV has loaded internal parameter set)
Read Result
Green
S
tart option: S
TART WITH
C
OPY
I
NTERN ->
E
XTERN
:
Blinks constantly together with the "Device Ready" LED
1)
Reading mode Device Ready
Green
Lights up constantly
Extinguishes with new operating mode/function
Sensor
Green
Lights up if reading diode is active
(The laser diode is activated/deactivated by reading pulse)
Lights up constantly in Free-running mode, since laser diode is always
active
Read Result Green LED is
linked
to the "Result 2" switching output and indicates the selected result
status for the defined pulse duration of the output.
Lights up after a successful read (default: Good Read)
Lights up if the match code comparison is active, the bar code read matches the
specified match code(s) and the corresponding result status output is selected
for the "Result 2" output
Data Yellow
Flickers when the CLV transfers data to the host on the host interface
Percentage Sensor
Green
Lights up constantly, as Free-running mode is active
evaluation Read Result
Green
Behavior depends on the reading quality:
Extinguishes if reading rate < 30 %
Blinks twice a second if reading rate 30 % ... 70 %
Blinks five times a second if reading rate 70 % ... 90 %
Lights up constantly if reading rate > 90 %
Adjusting mode Sensor
Green
Lights up c
onstantly
, as Free-running mode is active
Show CP-limits Sensor
Green
Blinks bright/dark alternately, in the frequency with which the scan line is (partially)
masked out
1) Set the start option to S
TART
WITH
THE
INTERNAL
P
ARAMETERS
on the D
EVICE
C
ONFIGURATION
tab in the "CLV-Setup" program. Download to CLV!
Table 3-2: Meaning of LEDs: CLV without external parameter memory