Operating Instructions Chapter 10
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-67
Appendix
Entering a bar code using a terminal/PC keyboard
1. Connect the terminal /PC with Terminal Emulation program to the terminal interface on
the CLV (via AMV/S 60).
For the pin assignment, see Chapter 5.5.5 Connecting the CAN
interface, Page 5-15.
2. Set the communication parameters and data output format as shown in
Table 10-9.
3. Enter the data content of the bar code on the keyboard.
The terminal sends the individual characters to the CLV immediately.
Use the backspace key to correct input errors.
4. Terminate the data content with the control character <CR>.
The CLV then interprets all further characters as a new data string and ignores other
control characters. The data content itself must not contain any control characters.
5. Once the active reading pulse has ended, the CLV sends the data received from the PC
to the host via the host interface.
Entering bar codes using a handheld scanner with decoder
1. Connect the handheld scanner with decoder to the terminal interface of the CLV (via
AMV/S 60).
For the pin assignment,
see
Chapter 5.5.5 Connecting the CAN interface,
Page 5-15.
2. Set the data format and communication parameters on the handheld scanner as shown
in
Table 10-9.
3. Read the bar code with the handheld scanner.
Once the active reading pulse has ended, the CLV sends the data received from the PC
to the host via the host interface.
If you are using the ST 1100 decoder from SICK, for example, set the communication para-
meters and data output as shown in
Table 10-10
.
Parameter Value
Data transmission rate 9 600 bit/s
Data bits 8
Parity None
Stop bits 1
Data output format Data terminator
e. g. 1234 CR
Table 10-9: Communication parameters on the terminal/PC for the auxiliary input
Parameter Value
Terminal ID Unassigned
WA Network No
ACK/NAK No
Baud rate 9 600 bit/s
Data bits 7
Parity Space
Configuration RS 232
Preamble (Header) Clear
Postamble (Terminator) CR
Table 10-10: Communication parameter settings for the ST 1100 decoder
Comentarios a estos manuales