Chapter 2 Online Help
ICR890
8 © SICK AG · Division Auto Ident · Germany · All rights reserved 8012178/0000/2008-01-28
ICR890
Image capture properties Use the parameters of the Image capture properties group to set the parameters for image
recording.
Parameters Function
Left edge of conveyor Enter maximum distance in Y direction to the reference point.
If applicable, select unit.
Right edge of conveyor Enter minimum distance in Y direction to the reference point.
If applicable, select unit.
Maximum scanning height Enter maximum object height (distance in Z direction to the refer-
ence point).
If applicable, select unit.
Level of conveyor Enter the height of the conveyor level to the reference point.
If applicable, select unit.
Parameters Function
Digital zoom Activate/Deactivate whether the image is to be recorded dis-
tance-independently with square resolution.
Zoom hysteresis Enter threshold for digital zoom switching.
If applicable, select unit.
Dynamic scanfrequency Activate/Deactivate automatic adjustment of the scanfrequency
to the conveyor speed.
Skew dependent gain adaption Activate/Deactivate adjustment of the image brightness to the
skew angle (only when reading from the side).
Gain adjustment factor Enter the static brightness.
Image resolution Adjust the image resolution to the maximum codelabel distance.
The image resolution depends on the focal length of the lens (e.g.
135 mm):
Codelabel distance 2 m: 250 dpi
Codelabel distance 2.5 m: 200 dpi
Codelabel distance 3 m: 170 dpi
CCD-line mirroring Reverse the reading direction of the CCD by 180°.
Depending on the installation situation it is necessary to guaran-
tee correct image capture.