SICK ICR890 Instrucciones de operaciones Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
Chapter 2 Online Help
ICR890
22 © SICK AG · Division Auto Ident · Germany · All rights reserved 8012178/0000/2008-01-28
ICR890
2.1.5.6 Code 128
C
ODE 128 is an alphanumeric code that can indicate the complete ASCII character set with
three character sets (set A, B and C). A check-digit test is always available.
! Character set A includes digits, uppercase letters and special characters.
! Character set B includes digits, uppercase and lowercase letters.
! Character set C only includes digits, but with a double density.
It is possible to start with one of these sets and to switch to another character set within the
code. C
ODE 128 is multiple-valued code (valency 4).
Fig. 2-12: Code 128 example
General Use the parameters of the General group to configure the reading conditions for the code
family C
ODE 128.
Length Use the parameters of the Length group to configure testing of the barcode length.
EAN 128 Use the parameters of the EAN 128 group to assign the function characters FC1. These
function characters identify the code as code type EAN 128. They can be at the beginning
or in the middle of the code.
Fig. 2-13: EAN 128 example
Parameters Function
Code 128
Activate/Deactivate scanning of code type CODE 128.
EAN 128
Activate/Deactivate scanning of code type
EAN 128.
Multiread Enter the minimum number of required successful readings that
must be achieved to accept a barcode as valid.
Parameters Function
Code length mode Select the type of code length test.
Interval Enter minimum length of barcode.
Enter maximum length of barcode.
Only barcodes with lengths between these two values are read.
Fixed codelengths Enter required lengths of barcode.
Only barcodes with the entered lengths are read.
Parameters Function
FC1 value on first position Enter FC1 values that have to be positioned at the beginning of
codes that are to be read.
FC1 value within code Enter FC1 values that have to be positioned in the middle of
codes that are to be read.
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 41 42

Comentarios a estos manuales

Sin comentarios