Online Help Chapter 2
ICR890
ICR890
8012178/0000/2008-01-28 © SICK AG · Division Auto Ident · Germany · All rights reserved 17
2.1.5.1 Codabar
The code type C
ODABAR consists of a character set of 16 characters (10 digits, 6 special
characters).
Fig. 2-6: Codabar example
General Use the parameters of the General group to configure the reading conditions for code type
C
ODABAR.
Length Use the parameters of the Length group to configure testing of the barcode length.
Parameters Function
Multiread Enter the minimum number of required successful readings that
must be achieved to accept a barcode as valid.
Start/Stop identical Set whether only barcodes with identical start and stop charac-
ters are to be read.
Transmit start/stop Activate/Deactivate output of the start and stop character
together with code content.
Check-digit test Select the type of check-digit test.
Parameters Function
Code length mode Select the type of code length test.
Interval Enter minimum length of barcode.
Enter maximum length of barcode.
Only barcodes with lengths between these two values are read.
Fixed codelengths Enter required lengths of barcode.
Only barcodes with the entered lengths are read.