Technische Daten
1192007-11-27 SICK CATALOGUE AUTOMATIC IDENTIFICATION TECHNOLOGY
Technical data
ICR840-2
Type ICR840-2A High Density ICR840-2B Standard ICR840-2C Mid Range ICR840-2D Long Range
Front reading window ICR840-2A0020
(Order no. 1042896)
ICR840-2B0020
(Order no. 1042277)
ICR840-2C0020
(Order no. 1042279)
ICR840-2D0020
(Order no. 1043547)
Side reading window ICR840-2A1020
(Order no. 1042897)
ICR840-2B1020
(Order no. 1042338)
ICR840-2C1020
(Order no. 1042885)
ICR840-2D1020
(Order no. 1043546)
Resolution 0.10 ... 2 mm 0.15 ... 2 mm 0.25 ... 2 mm 0.30 ... 2 mm
Focal position 50 mm 80 mm 115 mm 145 mm
Light source Illumination LEDs: visible red light (Ʈ = 617 ± 15 nm)
MTBF of LEDs 20,000 h
LED class Class 1 pursuant to EN/IEC 60825-1
Image refresh rate 25 Hz at 1.3 Megapixel
Ambient light compatibility 2,000 lx
Bar code types Code 39, Code 128, Codabar, EAN, EAN 128, UPC, 2/5, Interleaved, Pharmacode, RSS limited
Bar code length Max. 50 characters (max. 4,000 characters across all codes per reading interval)
2D code types Data Matrix ECC200
2D code size To ISO / IEC 16022
No. of codes per image 1 ... 50
No. of codes per reading interval 1 ... 50
Optical indicators 4 x LED (status indicator)
Acoustic indicator Beeper, can be switched off and assigned to a function for result status indication
Reading pulse “Sensor 1” switching input/free-running/serial interface
“Host” data interface RS-232 or RS-422/-485, 300 Bd ... 57,600 Bd, variable data output format
“Ethernet” data interface 10/100 Mbit/s, TCP/IP, FTP
AUX” data interface RS-232, 9,600 bd, 8 data bits, no parity, 1 stop bit, fixed output format
Digital switching inputs 2 (“Sensor 1”, “Sensor 2”)
Digital switching outputs 2 (“Result 1”, “Result 2”); Result 1: low-side switch, Result 2: high-side switch
Electrical connection 15-pin D Sub HD connector, cable length 0.9 m/RJ-45 socket
Operating voltage/
power consumption
15 V ... 30 V DC/max. 13 W
Housing Zinc die-cast
Electrical safety To EN 61010-1
Protection class III, to EN 61140
Enclosure rating IP 65, to EN 60529; A2, with mounted adapter frame and IP 65 Ethernet cable or with mounted adapter
frame and IP 65 cover.
IP 30 without adapter frame and cover or with standard Ethernet cable.
EMC/vibration/shock tested To EN 61000-6-2 and EN 61000-6-4 / EN 60068-2-6 / EN 60068-2-27
Weight Approx. 900 g with connecting cable
Operating/storage temperature 0 °C ... 40 °C / –20 °C ... +70 °C
Max. rel. humidity 90 %, non condensing